MIB Reference Manual (Version 3.0)

4-36 MIB Reference Manual Version 3.0
FCSwitch MIB Object Types
4
swFCPortOpStatus [swFCPortTable]
Syntax
Access Read-only
Status Mandatory
Description The operational status of the port.
swFCPortAdmStatus [swFCPortTable]
Syntax
Access Read-write
Status Mandatory
Description The desired state of the port. A management station may place the port in a desired state by setting
this object accordingly.
The 3 (testing) state indicates that no user frames can be passed. As the result of either explicit
management action or per configuration information accessible by the switch, swFCPortAdmStatus
is then changed to either the 1 (online) or 3 (testing) states, or remains in the 2 (offline) state.
Value Declaration Description
Integer 0 (unknown)
1 (online)
2 (offline)
3 (testing)
4 (faulty)
The port module is physically absent.
User frames can be passed.
No user frames can be passed.
No user frames can be passed.
The port module is physically faulty.
Value Declaration Description
Integer 1 (online)
2 (offline)
3 (testing)
4 (faulty)
User frames can be passed.
No user frames can be passed.
No user frames can be passed.
No user frames can be passed.