MIB Reference Manual (Version 3.0)

MIB Reference Manual Version 3.0 4-23
FCSwitch MIB Object Types
4
swSensorInfo [swSensorTable]
Syntax Display String of size 0 to 255
Access Read-only
Status Mandatory
Description Additional displayable information on the sensor. In V2.x, it contains the sensor type and number
in textual format. For example, Temp 3 or Fan 6.
Note: For swSensorIndex 1 through 5, valid return values include:
Temp #1
Temp #2
Temp #3
Temp #4
Temp #5
For swSensorIndex 6 through 11, valid return values include:
Fan #1
Fan #2
Fan #3
Fan #4
Fan #5
Fan #6
For swSensorIndex 12 and 13, valid return values include:
Power Supply #1
Power Supply #2
swTrackChangesInfo
Syntax Display String of size 0 to 256
Access Read-only
Status Mandatory
Description Track changes string. For trap only.
Note: If there are no events to track, the default return value is “No event so far”.
If there are events to track, the following are valid return values:
Successful login
Unsuccessful login
Logout
Configuration file change from task [name of task]
Track-changes on