MIB Reference Manual (Version 3.0)

2-26 MIB Reference Manual Version 3.0
Fibre Alliance MIB Object Types
2
connUnitSensorIndex [connUnitSensorTable]
Syntax Integer of size 1 to 2147483647
Access Read-only
Status Mandatory
Description A unique value among all connUnitSensorEntrys with the same value of connUnitSensorUnitId, in
the range between 1 and connUnitNumSensor.
Note: The valid value for the FC Entry Switch 8B and FC Switch 8B: 11
The valid value for the FC 16B: 13
connUnitSensorName [connUnitSensorTable]
Syntax Display String
Access Read-only
Status Mandatory
Description A textual identification of the sensor intended primarily for operator use.
Note: Each contains the name of sensor in textual format. (For example, Temp #1, Fan #2, and so
on.)
connUnitSensorStatus [connUnitSensorTable]
Syntax
Access Read-only
Status Mandatory
Description The status indicated by the sensor.
Note: Nominal =3 (ok). Not nominal = 5 (failed).
Table 2-10
Value Declaration Description
Integer 1 (unknown)
2 (other)
3 (ok)
4 (warning)
5 (failed)
The sensor indicates ok.
The sensor indicates a warning.
the sensor indicates failure.