MIB Reference Manual (Version 3.0)

MIB Reference Manual Version 3.0 2-17
Fibre Alliance MIB Object Types
2
connUnitPrincipal [connUnitTable]
Syntax Integer
Access Read-only
Status Mandatory
Description Whether this connectivity unit is the principal unit within the group of fabric elements. If this value
is not applicable, return unknown.
Note: If the switch is principal, this is set to 3 (yes), otherwise, it is set to 2 (no).
connUnitNumSensors [connUnitTable]
Syntax Integer
Access Read-only
Status Mandatory
Description Number of sensors in the connUnitSensorTable.
Note: The number of sensors for the FC Entry Switch 8B and FC Switch 8B: 11 (5 temp + 5
fans + 1 power supply).
The number of sensors for the FC 16B: 13 (5 temp + 6 fans + 2 power supplies).
connUnitStatusChangeTime [connUnitTable]
Syntax TimeTicks
Access Read-only
Status Deprecated
Description The sysuptime timestamp (in centiseconds) at which the last status change occurred for any
members of the set. In other words, this is the latest timestamp that connUnitStatus or
connUnitPortStatus changed.
Note: This is the same as statusChangeTime.
Table 2-6
Value Declaration Description
Integer 1 (unknown)
2 (no)
3 (yes)