HP Surestore FC 1Gb/2Gb Switch 8B Getting Started Guide
32 Getting Started Guide
Step 12: Complete Zoning Activities
Step 13: Save Active Zone Set
For complete instructions on configuring the HP Director FC-64 switch see
“Checklist for Merging Fabrics” in the Merging Heterogeneous Fabrics
Instructions white paper on the FC Entry Switch 8B or FC Switch 8B
Documentation CD.
HP Surestore VA 7400
The FC Entry Switch 8B or FC Switch 8B also can support a 2Gb
connection to an HP Surestore Virtual Array 7400. Set the port speed to
2Gb using the telnet command
portCfgSpeed.
Use the Virtual Front Panel (VFP) on the VA 7400 and configure the device
as follows:
1. Change the controller port data rate to 2 Gbits/s
a. To change the port data rate to 2 gigabits/second for controller 1, enter:
vfpmgr -S 2 -c 1
When prompted to reset, enter no.
b. To change the port data rate for controller 2, enter:
vfpmgr -S 2 -c 2
When prompted to reset, enter no if additional settings must be
changed. If all changes have been made, enter
yes to reset the array.
2. Change the controller port topology.
a. To change the port topology for controller 1 enter the following
command, selecting
4 for Direct Fabric Attach:
vfpmgr -t 4 -c 1
When prompted to reset, enter no.
b. To change the port topology for controller 2 enter the following
command, using the same topology value used for controller 1:
vfpmgr -t 4 -c 2
When prompted to reset, enter no if additional settings must be
changed. If all changes have been made, enter
yes to reset the array.