HP Surestore FC 1Gb/2Gb Switch 8B Getting Started Guide

Setup 27
b. Then enter the following to display the configuration prompts:
configure.
c. Enter “y” after the prompt “Fabric parameters”. For example:
Fabric parameters (yes, y, no, n): [no] y
d. Enter a unique domain ID: Domain: (1..239) [1] 3.
e. Complete the remaining prompts or press CTRL+D to accept the
remaining settings without completing all the prompts.
f. Re-enable the switch by entering the following: switchEnable.
5. Optional: Specify any custom status policies for the fabric by completing
the following steps:
a. Enter the following at the prompt: switchStatusPolicySet.
b. Customize the status policies as desired. To completely deactivate the
alarm for a particular condition, enter “0 at the prompt for that
condition.
6. If necessary, install or change the SFPs (small form factor pluggable
media) by completing the following steps:
Note The ports selected for use in trunking groups must meet specific
requirements. For a list of these requirements, refer to the ISL Trunking
User’s Guide.
a. Remove the shipping plugs from the ports to be used.
b. Position the SFP so that the key (the tab near the cable-end of the SFP)
is on top and insert the SFP into the port until it is firmly seated and
the latching mechanism clicks. For instructions specific to the SFP
type, refer to the SFP manufacturers documentation.
Note The SFP is keyed so that it can only be inserted with the correct
orientation into the port. If the SFP does not slide in easily, ensure it is
correctly oriented.
7. Connect the cables to the SFPs as appropriate to the fabric topology.
Position each cable so that the key (the ridge on one side of the cable
connector) is aligned with the slot in the SFP. Then, insert the cable into