Fabric OS Reference Manual (Version 3.0)

Fabric OS Reference 2-13
Error Messages
2
DIAG-PORTSTOPPED
Err#3874
[spinSilk]
Port is no longer transmitting, as
indicated by the Number Of Frames
Transmitted counter being stuck at N
frames
ASIC, GBIC module
or fiber cable failure
Replace mainboard
assembly, GBIC
module or fiber
cable
DIAG-PORTWRONG
Err#3078
[crossPortTest]
Frame erroneously received by port M
instead of the intended port N
ASIC failure Replace mainboard
assembly
DIAG-POST_SKIPPED
Err# 0004
[switch initialization]
POST is skipped Informational Only None required
DIAG-REGERR
Err#0B15, 0415
[portRegTest,
sramRetentionTest]
Data read from ASIC register or ASIC
SRAM did not match data previously
written into same location
ASIC failure Replace mainboard
assembly
DIAG-REGERR_UNRST
Err#0B16, 0416
[portRegTest,
sramRetentionTest]
Port failed to unreset ASIC failure Replace mainboard
assembly
DIAG-STATS
Err#2660-2662, 3060 - 3062
[portLoopback Test,
crossPortTest]
Port counter value did not match the
number of frames actually transmitted.
Possible counters reporting:
FramesTx - number of frames
transmitted
FramesRx - number of frames
received
Cl3FrmRx - number of Class 3
frames received
ASIC, GBIC module
or fiber cable failure
Replace mainboard
assembly, GBIC
module or fiber
cable
DIAG-TIMEOUT
Err#266F, 306F, 386F
[portLoopbackTest,
crossPortTest,
centralMemoryTest]
For portLoopbackTest and crossPortTest:
Port failed to receive frame within
timeout period
For centralMemoryTest
Port failed to detect an interrupt
within the timeout period
ASIC, SFP module
or fiber cable failure
Replace mainboard
assembly, SFP
module or fiber
cable
DIAG-XMIT
Err#2271, 2671, 3071, 3871
[portLoopbackTest,
crossPortTest, spinSilk,
camTest]
Port failed to transmit frame ASIC failure Replace mainboard
assembly
Table 2-4 Diagnostic Error Messages (Continued)
Message Description Probable Cause Action