Fabric OS Reference Manual (Version 3.0)
Fabric OS Reference 2-13
Error Messages
2
DIAG-PORTSTOPPED
Err#3874
[spinSilk]
Port is no longer transmitting, as
indicated by the Number Of Frames
Transmitted counter being stuck at N
frames
ASIC, GBIC module
or fiber cable failure
Replace mainboard
assembly, GBIC
module or fiber
cable
DIAG-PORTWRONG
Err#3078
[crossPortTest]
Frame erroneously received by port M
instead of the intended port N
ASIC failure Replace mainboard
assembly
DIAG-POST_SKIPPED
Err# 0004
[switch initialization]
POST is skipped Informational Only None required
DIAG-REGERR
Err#0B15, 0415
[portRegTest,
sramRetentionTest]
Data read from ASIC register or ASIC
SRAM did not match data previously
written into same location
ASIC failure Replace mainboard
assembly
DIAG-REGERR_UNRST
Err#0B16, 0416
[portRegTest,
sramRetentionTest]
Port failed to unreset ASIC failure Replace mainboard
assembly
DIAG-STATS
Err#2660-2662, 3060 - 3062
[portLoopback Test,
crossPortTest]
Port counter value did not match the
number of frames actually transmitted.
Possible counters reporting:
• FramesTx - number of frames
transmitted
• FramesRx - number of frames
received
• Cl3FrmRx - number of Class 3
frames received
ASIC, GBIC module
or fiber cable failure
Replace mainboard
assembly, GBIC
module or fiber
cable
DIAG-TIMEOUT
Err#266F, 306F, 386F
[portLoopbackTest,
crossPortTest,
centralMemoryTest]
For portLoopbackTest and crossPortTest:
• Port failed to receive frame within
timeout period
• For centralMemoryTest
• Port failed to detect an interrupt
within the timeout period
ASIC, SFP module
or fiber cable failure
Replace mainboard
assembly, SFP
module or fiber
cable
DIAG-XMIT
Err#2271, 2671, 3071, 3871
[portLoopbackTest,
crossPortTest, spinSilk,
camTest]
Port failed to transmit frame ASIC failure Replace mainboard
assembly
Table 2-4 Diagnostic Error Messages (Continued)
Message Description Probable Cause Action