Fabric OS Reference Manual (Version 3.0)

Fabric OS Reference 2-11
Error Messages
2
DIAG-ERRSTAT
Err#2640-2647, 3040-3047,
3840-3847
[portLoopbackTest,
crossPortTest, spinSilk]
Port Error Statistics counter is non-zero,
meaning an error was detected when
receiving frames.
One of the following status errors
occurred.
Enc_in Encoding error, inside
frame
CRC_err – Cyclic redundancy
check on frame failed
TruncFrm – Truncated frame
FrmTooLong – Frame too long
BadEOF – Bad end of file
Enc_out – Encoding error, outside
frame
BadOrdSet – Bad symbol on
fiber-optic cable
DiscC3 – Discarded Class 3 frames
ASIC, mainboard,
SFP module or fiber
cable failure
Replace mainboard
assembly, SFP
module or fiber
cable
DIAG-INIT
Err#264F, 304F, 384F
[portLoopbackTest,
crossPortTest, spinSilk]
Port failed to go active in the loopback
mode requested
ASIC, main board,
SFP module or fiber
cable failure
Replace mainboard
assembly, SFP
module or fiber
cable
DIAG-INTNIL
Err#2031
[cmiTest]
ASIC failed to get a CMI error
(interrupt)
ASIC failure Replace mainboard
assembly
DIAG-INTNOTCLR
Err#102C
[centralMemoryTest]
The interrupt bit could not be cleared ASIC failure Replace mainboard
assembly
DIAG-LCMEM
Err#1027
[centralMemoryTest,
cmemRetentionTest]
Data read from the Central Memory
location did not match data previously
written into the same location
ASIC failure Replace mainboard
assembly
DIAG-LCMEMTX
Err#1F27, 1028
[centralMemoryTest]
Central Memory transmit path failure:
ASIC 1 failed to read ASIC 2 using the
transmit path
mainboard failure Replace mainboard
assembly
Table 2-4 Diagnostic Error Messages (Continued)
Message Description Probable Cause Action