Fabric OS Reference Manual (Version 3.0)

2-10 Fabric OS Reference
Error Messages
2
DIAG-CMERRTYPE
Err#102A
[centralMemoryTest]
Port got the wrong CMEM error type ASIC failure Replace mainboard
assembly
DIAG-CMICKSUM
Err#2036
[cmiTest]
CMI message received failed bad
checksum test
ASIC or mainboard
failure
Replace mainboard
assembly
DIAG-CMIDATA
Err#2035
[cmiTest]
CMI data received did not match data
transmitted
ASIC or mainboard
failure
Replace mainboard
assembly
DIAG-CMIINVCAP
Err#2034
[cmiTest]
Unintended ASIC erroneously got CMI
capture flag
ASIC or mainboard
failure
Replace mainboard
assembly
DIAG-CMINOCAP
Err#2033
[cmiTest]
CMI intended receiver ASIC failed to get
CMI capture flag
ASIC or mainboard
failure
Replace mainboard
assembly
DIAG-CMISA1
Err#2032
[cmiTest]
An attempt to send a CMI message from
ASIC to ASIC failed
ASIC failure Replace mainboard
assembly
DIAG-CMNOBUF
Err#1029
[centralMemoryTest]
Port could not get any buffer ASIC failure Replace mainboard
assembly
DIAG-DATA
Err#266E, 306E
[portLoopbackTest,
crossPortTest]
Payload received by port did not match
payload transmitted
mainboard, GBIC
module or fiber cable
failure
Replace mainboard
assembly, GBIC
module or fiber
cable
Table 2-4 Diagnostic Error Messages (Continued)
Message Description Probable Cause Action