Fabric OS Reference Manual (Version 3.0)
1-274 Fabric OS Reference
Telnet Commands
1
The test flow for each SRAM is as follows:
1. Fill RAM with alternating FFFF 0000 pattern. (Subtest 1: turboram memory fill)
2. For each incrementing address read FFFF 0000 pattern and write 0000 FFFF. (Subtest 2:
turbo-ram r-m-w inc 1)
3. For each incrementing address read 0000 FFFF pattern and write FFFF 0000. (Subtest 3:
turbo-ram r-m-w inc 2)
4. For each decrementing address read FFFF 0000 pattern and write 0000 FFFF. (Subtest 4:
turbo-ram r-m-w dec 1)
5. For each decrementing address read 0000 FFFF pattern and write FFFF 0000. (Subtest 5:
turbo-ram r-m-w dec 2)
6. Repeat steps 1-5 with AAAA 5555 pattern.
Operands This command has the following operand:
passcount Specify the number of turboRamTest passes to execute this test.
Example To execute this test three times:
See Also portRegTest
ramTest
centralMemoryTest
cmiTest
camTest
sramRetentionTest
switch:admin> turboRamTest 3
Running Turbo RAM Test ........ passed.