Fabric OS Reference Manual (Version 3.0)
1-202 Fabric OS Reference
Telnet Commands
1
psShow
Display power supply status.
Synopsis psShow
Availability All users
Description Use this command to display the switch power supply status.
The display format varies with switch model and number of power supplies present.
The status of each supply is shown as:
OK Power supply present and functioning correctly.
absent Power supply not present.
faulty Power supply present but faulty (no power cable, power switch turned off, fuse
blown, or other internal error).
After the status line, a power supply identification line may be shown. If present, this line contains
manufacture date, part numbers, serial numbers, and other identification information.
Operands None.
Example To view the status of the power supply for the current switch:
See Also fanShow
tempShow
switch:admin> psShow
Power Supply 1 is OK
9835,DH000000208,60-0000734-01, A,00001, E108302A,01, 803350
Power Supply 2 is OK
9839,DH000000253,60-0000734-01, A,00001, E108302A,01, 803522