HP StorageWorks Enterprise Virtual Array release notes (XCS 09522000) (5697-0233, November 2009)

Addressed an issue of incorrect severity reporting for disk enclosure inter-I/O module communic-
ation issues.
Previously HP recommended that customers disable the Enable time sync feature in HP Command
View EVA to avoid an issue in controller software for server-based management configurations.
This feature can now be re-enabled as per published best practices.
The following issues were fixed in XCS 09501x00 and are included in XCS 09522000:
Fixed an issue where an Emulex Fibre Channel adapter, mezzanine card, or combination card
in an HP-UX 11.23 IA64 or 11.31 IA64 server failed to discover LUNs presented from an EVA4400
or EVA6400/8400 running XCS 09500000, 09501000, or 09501100. The affected 4 Gb
Emulex PCI-e HBAs are AD299A, AD335A, AD221A, AD222A, and AD393A and all Emulex
mezzanine cards, including those in the BL870 and BL860 blade servers.
Addressed a condition where a disk group was declared inoperative due to missing disk drives.
Fixed an issue where an unrecovered read media error from a disk drive caused a Unit Stalled
Too Long error to occur or host I/O to stall on a LUN.
Fixed an issue where a recursive termination could occur when a failed or missing disk drive was
being accessed during a rebuild parity operation and a subsequent controller resynchronization.
Fixed an issue where a recursive termination could occur during snapshot creation.
Fixed an issue where high snapshot write activity could lead to a controller reset.
Fixed an issue where Fibre Channel switches using Extended Link Services (ELS) caused a controller
reset.
Improved internal controller communication to reduce failure reporting.
Improved I/O module firmware to reduce resets and loop disruption.
Improved controller software to address controller replacement issues.
Fixed an incorrect host port speed reporting issue.
Improved controller role transition under a certain controller failure condition.
Addressed an issue where a Linux host could see an unresponsive host port after a controller failure.
Operating systems
For complete information about operating system specifications and supported configurations, see
the Single Point of Connectivity Knowledge (SPOCK) at http://www.hp.com/storage/spock. You
must sign up for an HP Passport to enable access.
Upgrade and downgrade paths
CAUTION:
EVA4400 controllers that have a label stating Min FW 09522000 affixed to them cannot be
downgraded or they will be rendered inoperable.
For details about supported upgrade paths to XCS 09522000, see Table 3.1, Upgrade support for
controller software versions, in the HP StorageWorks Enterprise Virtual Array compatibility reference.
For supported downgrade paths from XCS 09522000, see Table 3.2, Downgrade support for controller
software versions in the compatibility reference.
For upgrade instructions, see the HP StorageWorks Enterprise Virtual Array updating product software
guide (XCS 09522000).
HP StorageWorks Enterprise Virtual Array release notes (XCS 09522000) 5