HP StorageWorks Controller Enclosure 4Gb Array Controller Replacement Instructions (631505-001, August 2010)

1. Halt I/O to the controller with HP Command View EVA:
a. In the navigation pane, select Storage System > Hardware >
Controller Enclosure.
b. Select the appropriate controller (Controller 1 or Controller 2)
to halt.
c. Click the Shut down tab.
d. In the Halt Controller section of the Shut Down Controller
window, click Halt. This halts controller processing while the
power remains on.
NOTE:
In the rare instance when you cannot halt I/O to
the controller, go to Shutting down the controller
enclosure to shut down the controller enclosure.
Otherwise, continue with Step 2. If you shut down
the controller enclosure, all I/O is halted.
In addition, exercise care when replacing a
controller while the enclosure is powered off to
ensure that inadvertent controller software
upgrades or downgrades will not occur.
2. Disconnect the Fibre Channel cables from the halted controller.
Ensure they are marked to facilitate reconnecting later.
3. Remove the controller.
a. Move the mounting latch to the right (1, Figure 3). The controller
will slightly eject from the enclosure.
b. Position one hand under the controller, and with the other hand,
pull the controller out of the enclosure (2).
Figure 3 Removing a controller
.
4. Push the blue button on top of the controller module (1, Figure 4)
and slide off the cover (2). Observe proper anti-static guidelines.
Figure 4 Removing the controller cover
.
5. Refer to Figure 5 for the location of the two DIMMs on the controller.
2. Slot 2 (cache memory)1. Slot 1 (policy memory)
Figure 5 Location of controller DIMMs
.
6. Press the retaining clips outward to unlock each DIMM socket (1,
Figure 6). This action releases the modules, and partially lifts the
modules out of the socket.
Figure 6 Removing a DIMM
.
7. Lift out each DIMM (2).
Shutting down the controller enclosure
In the rare instance when you cannot shut down an individual EVA4400
controller, you must power off the EVA4400 controller enclosure before
removing a failed controller.
Power off the enclosure using one of the following methods:
Using HP Command View EVA
Page 3