HP StorageWorks Enterprise Virtual Array release notes (XCS 09522000) (5697-0233, November 2009)

You can download these documents from the following website:
http://www.hp.com/support/manuals
Under Storage, click Disk Storage Systems, and then select HP StorageWorks 4400 Enterprise Virtual
Array or HP StorageWorks 6400/8400 Enterprise Virtual Array under EVA Disk Arrays.
NOTE:
A full restart of both controllers is required only one time after HP Command View EVA and the
management module software is installed on the management module of the EVA4400. This is
applicable when upgrading to XCS 09006000 or later. Subsequent upgrades of controller software
or management module software, or upgrading HP Command View EVA on the management module
do not require another full restart.
HP StorageWorks SmartStart EVA Storage Kit
HP StorageWorks SmartStart EVA Storage is a CD-based wizard that you use on your Windows
Server 2003 system to install and configure HP Command View EVA. You can use HP Command
View EVA to configure, manage, and monitor the HP StorageWorks Enterprise Virtual Array (EVA)
storage system.
NOTE:
For the EVA4400, HP Command View EVA 9.1 is pre-installed on the controller enclosure management
module. You can still use HP SmartStart EVA Storage to configure application servers.
To bypass the HP SmartStart EVA Storage interface and manually run the HP Command View EVA
installer, go to the \bin\installers\CV directory on the CD.
HP SmartStart EVA Storage will install Windows MPIO DSM, which enables you to provision storage
from the array; and DSM Manager, which enables you to change the default settings of MPIO DSM.
SAN support
The HSV300 controller in the EVA4400 supports 1/2/4 Gb Fibre Channel communication, but
requires 4 Gb SFPs in the controller host ports. The HSV300-S supports up to 8 Gb communication
through the embedded switch ports.
The HSV400 controller in the EVA6400 and the HSV450 controller in the EVA8400 are enabled for
4 Gb/s on each Fibre Channel host path, but will also support 2 Gb/s and 1 Gb/s (with restrictions)
Fibre Channel host paths and components for backward compatibility.
NOTE:
1 Gb path and components have specific configuration requirements. For more information on
configuration requirements and support for 2 Gb and 4 Gb EVAs, see the
HP StorageWorks SAN
design reference guide
, which can be downloaded from the following website:
http://www.hp.com/support/manuals
Click Storage Networking under Storage, and then select HP StorageWorks SAN under HP
StorageWorks SAN Solutions.
6