HP StorageWorks ESL E-Series Ultrium FC Drive Replacement Instructions (December 2005)

11
Push the drive the rest of the way into the drive
bay, then tighten the captive screw to secure the
drive to the cluster.
Verify that the FC port LED on the FC interface
controller card is green.
14
The LED for the replaced
drive and its associated
cluster controller card LED
should be green.
15
Note: If needed, the tie wrap provided
with this kit can be used to help keep
the FC cables clear of the drive cluster
below by attaching the cables to the
drive handle.
12
If the drive did not power itself on, use the OCP
to power on the drive now.
a. From Menu, select the Ops button.
b. Use the Up and Down buttons to select the
drive, then press the Select button.
c. Use the Up and Down buttons to change the
drive to on-line, then press the Select button.
d. Select the Back button to return to Menu.
13
Use the Command View TL user interface to
reboot the interface controller card. Refer to
the HP StorageWorks Interface Manager and
Command View TL User Guide for detailed
procedures.