HP StorageWorks ESL E-Series Tape Library Users Guide (350799-010, September 2007)
Sense
key
ASC ASCQ
Messag e name / description
484
See
Table
22
VERTICAL HARDWARE FAILURE
• Remove any obstructions.
• Run the Robotics Self Test from the OCP.
485
See
Table
22
HORIZONTAL HARDWARE FAILURE
• Remove any obstructions.
• Run the Robotics Self Test from the OCP.
4
87
See
Table
22
DEPTH HARDWARE FAI LURE
• Remove any obstructions.
• Run the Robotics Self Test from the OCP.
4
88 00
WARNING SAFE TEMPERATURE EXCEEDED
This is a warning that the temperature in the librar y exceeds the normal
operational temperature 40
o
C(104
o
F).
48801
MAXIMUM TEMPERATURE EXCEEDED
The robot in the overheated cabinet turns off and remains off until th e
temperaturereturnstoanacceptablelevel.ForLTO,theacceptablelevel
is 52
o
C(127
o
F); for SDLT, the acceptable level is 49
o
C(120
o
F).
• Check whether the a ir filters need to be replaced.
• Check for fan failure.
• Lower the ambient temperature.
4
89 00–FF
VISION HARDWARE FAILURE
Vision internal failure .
48A
02
CALIBRATION FAILURE
Check slots, cartridges, targets, and all internal elements. Verify that the
panels are properly seated and that doors are closed.
4
8B
See
Table
22
CLM HARDWARE FAILURE
CLM failure.
4
8C 06
LOAD PO
RT DOOR OPEN
Load po
rt door unlocked but failed to open.
4
8E 02
SCSI UPGRADE TRANSFER FAILED
A data transfer error or a data storage error was received during the
firmware upgrade.
48E03
CABINET CONTROLLER UNABLE TO UPLOAD
Unable to upload firmware to the cabinet controller.
• Retry the download.
• Check cable connections.
• Replace Smart M e dia and retry.
4
8E
04
ROBOTICS CONTROLLER UNABLE TO UPL OAD
Unable to upload firmware to the robotic controller. Verify that the
firmware image is correct and attempt to update again.
4
F2 00
I2C BUS COMMUNICATION FAILURE
Unable to communicate with the drive cluster.
• Check I2C cable connection on the drive cluster.
• Check that the cluster is powered on.
• Check the LED status of the cluster controller.