Interface Manager card not powered on or in ready state
Power on the library. Observe status and link LEDs.
Interface Manager must be at rmware I120 or higher on an ESL E-series library.
Interface Manager must be at rmware I130 or higher if connected to an e2400-FC 2G.
Interface Manager must be at rmware 1.6.1 or higher if connected to an e2400–FC 4G.
Incorrect IP address
Verify tha t the correct IP address of the Interface Manager card is entered in Command View TL.
See the HP StorageWorks ESL E-Series unpacking and installation guide for information on
obtaining the correct IP address using the O CP.
Congure Command View TL with the correct IP address. See the HP StorageWorks Interface
Manager and Command View TL user guide for information on adding a library or visit
h
ttp://www.hp.com/support/cvtl.
Interface Ma
nager card does not detect one or more FC interface controllers
Bad network connection
Verify that
the Interface Manager card is properly connected to the FC inter face controllers and
that the cables are good.
Use LEDs to troubleshoot Ethernet cabling.
See the HP S
torageWorks ESL E-Series unpacking and installation guide for more information.
Incorrect
interface controller, or controller has less than minimum required rmware
Make sure that the e2400-160 interface controller h as lettering to the side of the ports. If
lettering is above or below the ports, then the wrong controller type was installed. Contact
your servi
ce provider.
NOTE:
If you hav
e the wrong controller t ype, it might still work if the rmware level is at least 5.3.06, the
controll
er is set to DHCP, and its defaults are restored.
Update the rmwaretoversion5.6.78orhigheronane2400160ande2400FC2Ginterface
controllers and version 5.7.1 on the e2400–FC 4G; then restore defaults on the interface controller.
DefectiveInterfaceManagercardorFCinterfacecontroller
Observe status and link LEDs. Replace defective card o r controller.
Interface Manager card does not detect drives or library
SCSI cables not connected properly
Check cabling connections.
SCSI settings or termination not set properly
Check the SCSI settings for the device.
Check that the SCSI bus is properly terminated and ensure the terminator LEDs indicate a
normal state (green).
Timing issues
Reset the corresponding FC interface controller.
Drivenotpoweredonorinreadystate
Make sure the drive isn’t set to off.
Troubleshoot the drive.