HP StorageWorks ESL E-Series Tape Library users guide (350799-010, October 2007)

Oneormoretapedrivesfailtospinupduringstart-up
Verify cable co
nnections and termination.
Make sure the OCP does not show the drive power as off.
Check that the power supplies are switched on for that level (clusters 0 - 5).
Check that the c
luster controller is properly cabled and ready.
OCP problems
This section describes corrective actions for OCP problems.
The OCP is blank
Conrm that p
ower is on.
Use Command View TL software or the Interface Manager’s command line interface to check
for errors on the OCP.
The OCP does not respond to buttons
Use Command View TL software or the Interface Manager’s command line interface to check
for errors on the OCP.
Contact an authorized eld service engineer.
An error message is displayed
Write dow
n the details of the error m essage, including the SK, ASC, and ASCQ numeric values.
Look up the code and try the sugg ested recovery procedures.
Press OK to clear the message.
Robotics problems
This section describes corrective actions for robotics problems.
The robo
t does not move at power on
Make sure all internal packing materials (foam pads, tie wraps, and shipping restraints) have
been re
moved.
Check the Stop button; make sure the library is on-line and not in the stopped” mode.
The picker partially grips a tape cartridge
Issue a Move Cartridge command using your application software to move the cartridge from
the picker to an empty storage bin.
If the problem continues, contact a eld service engineer.
The barcode reader fails
Verify that nothing obstructs the reader.
Make sure that approved bar-code labels are being used and are correctly applied.
Then
, restart the library. If the problem continues, c ontact your service provider.
74
Maintenance and troubleshooting