HP StorageWorks ESL E-Series Tape Library users guide (350799-010, October 2007)
Oneormoretapedrivesfailtospinupduringstart-up
• Verify cable co
nnections and termination.
• Make sure the OCP does not show the drive power as off.
• Check that the power supplies are switched on for that level (clusters 0 - 5).
• Check that the c
luster controller is properly cabled and ready.
OCP problems
This section describes corrective actions for OCP problems.
The OCP is blank
• Confirm that p
ower is on.
• Use Command View TL software or the Interface Manager’s command line interface to check
for errors on the OCP.
The OCP does not respond to buttons
• Use Command View TL software or the Interface Manager’s command line interface to check
for errors on the OCP.
• Contact an authorized field service engineer.
An error message is displayed
• Write dow
n the details of the error m essage, including the SK, ASC, and ASCQ numeric values.
Look up the code and try the sugg ested recovery procedures.
• Press OK to clear the message.
Robotics problems
This section describes corrective actions for robotics problems.
The robo
t does not move at power on
• Make sure all internal packing materials (foam pads, tie wraps, and shipping restraints) have
been re
moved.
• Check the Stop button; make sure the library is on-line and not in the “stopped” mode.
The picker partially grips a tape cartridge
• Issue a Move Cartridge command using your application software to move the cartridge from
the picker to an empty storage bin.
• If the problem continues, contact a field service engineer.
The barcode reader fails
• Verify that nothing obstructs the reader.
• Make sure that approved bar-code labels are being used and are correctly applied.
• Then
, restart the library. If the problem continues, c ontact your service provider.
74
Maintenance and troubleshooting