HP StorageWorks ESL E-Series Tape Library users guide (350799-010, October 2007)
Sense
key
ASC ASCQ
Messag e name / description
B
30 00
INCOMPATIBLE MEDIA
An attempt was made to move media to a destination element that is
incapable of receiving it. Make sure you are using the correct media
and that it is labeled with the correct barcode.
B
43
00
SCSI MESSAGE ERROR
Detected message error in message processing on the SCSI BUS.
• Verify termination.
• Verify SCSI cable connections.
• Check host status.
• Restart system.
B
47
00
SCSI P ARITY ERROR
SCSI Parity Error detected.
• Verify termination.
• Verify SCSI cable connections and cable length.
• Check host status.
• Restart the system.
B
48
00
INITIATOR DETECTED ERROR MESSAGE RECEIVED
B
80 01
TRANSFER FULL - AT END OF PLACE
Picker has cartridge in it at end of a pl ace operation (Move Medium
with a target other than the Transfer).
• Move cartridge to empty storage element using your application
software. Retry command.
• As a last resort, manually remove the tape from the robotics.
B
80 06
TRANSFER EMPTY - COMMAND ABORTED
Picker does not contain cartr idge at end of pick portion of the Move
Medium command.
B
80 10
LOAD RETRY FAILED
Library was unable to successfully load and thread the drive, even after
retries.
• Check drive alignment.
• Make sure the correct media for the drive is being used.
• If cartridge loads in another drive successfully, the original drive
may have failed.
B
80 0B
COMMAND ABORTED BY USER
Informational message. No action is necessary.
B
80 0D
CART
RIDGE PARTIALLY GRIPPED
• Issu
e a Move Medium command using your application software to
move the cartridge from the transfer element to an empty storage
element.
• If necessary, manually clear the media, recalibrate, then inventory
the library.
B
88 C0
TRA NSPORT FULL
The CLM c ontains a cartridge. I ssue a command to retrieve the cartridge
fromtheCLMandplaceitineitherabinoratapedrive.
B
8C 01
LOAD PORT LATCH FAILURE
The load port door was unlocked, but did not leave its current position
before time-out (30 seconds). This may be due to the door being stuck,
or in the case of a close operation, the operator not moving the door.
HP StorageWorks
121