HP StorageWorks ESL E-Series Tape Library users guide (350799-010, October 2007)
Sense
key
ASC ASCQ
Message name / description
4
F3 02
DRIVE COMMUNICATION TIMEOUT
The library is unable to communicate with a drive.
• Check the I2C cable, the cluster controller, and the cluster backplane
board.
• Check that the drive is properly seated in the bay.
• Swap the drive for a known-good drive and retry.
• Reseat SCSI cabling and termination.
4
F3 20
DRIVEUNLOADFAILEDORTIMEDOUT
The command to the drive to unl oad the tape failed to complete or timed
out. Retry the unload command. If it fails again, manually attempt to
eject the tape.
4
F3 21
DRIVE EJECT FAILED OR TIMED OUT
The command to the drive to eject a tape failed to complete or time
out. Retry the unload command. If it fails again, manually attempt to
eject the tape.
4
F3 22
DRIVELOADFAILEDORTIMEDOUT
The command to the drive to load a tape failed to complete or timed
out. Check drive logs for more information.
4F323
DRIVETHREADFAILEDORTIMEDOUT
Thecommandtothedrivetothreadatapefailedortimedout.Check
drive logs for more information.
5
04
07
DRIVE FW UPDATE IN PROGRESS
The drive can not perform indicated request because it is in the process
of updating it’s firmware . Wait until the firmware update is complete,
then retry the operation.
5
20 00
INVALID COMMAND OPERATION CODE
• Verify the host command format.
• Verify that the host soft ware application is supported, has up-to-date
patches, and is correctly configured.
• Verify that the library and its components have the current firmware.
5
21 01
INVALID ELEMENT ADD RESS
• Check Mode Sense data for correct element addresses.
• Verify that the host soft ware application is supported, has up-to-date
patches, and is correctly configured.
• Verify that the library and its components have the current firmware.
5
24
00
INVALID FIELD IN COMMAND DATA BLOCK
• Ensure all reserve fields are set to zero.
• Verify that the host soft ware application is supported, has up-to-date
patches, and is correctly configured.
• Verify that the library and its components have the current firmware.
5
25 00
LOGICAL UNIT IS NOT SUPPORTED
• Verify the logical unit field specified in th e comman d contains a
legitimate logical unit number.
• Check cabling to logical unit.
• Verify that the host soft ware application is supported, has up-to-date
patches, and is correctly configured.
• Verify that the library and its components have the current firmware.
116
Sense data values