HP StorageWorks ESL E-Series Tape Library users guide (350799-010, October 2007)

Sense
key
ASC ASCQ
Messag e name / description
484
See
Table
22
VERTICAL HARDWARE FAILURE
Remove any obstructions.
Run the Robotics Self Test from the OCP.
485
See
Table
22
HORIZONTAL HARDWARE FAILURE
Remove any obstructions.
Run the Robotics Self Test from the OCP.
4
87
See
Table
22
DEPTH HARDWARE FAI LURE
Remove any obstructions.
Run the Robotics Self Test from the OCP.
4
88 00
WARNING SAFE TEMPERATURE EXCEEDED
This is a warning that the temperature in the librar y exceeds the normal
operational temperature 40
o
C(104
o
F).
48801
MAXIMUM TEMPERATURE EXCEEDED
The robot in the overheated cabinet turns off and remains off until th e
temperaturereturnstoanacceptablelevel.ForLTO,theacceptablelevel
is 52
o
C(127
o
F); for SDLT, the acceptable level is 49
o
C(120
o
F).
Check whether the a ir lters need to be replaced.
Check for fan failure.
Lower the ambient temperature.
4
89 00–FF
VISION HARDWARE FAILURE
Vision internal failure .
48A
02
CALIBRATION FAILURE
Check slots, cartridges, targets, and all internal elements. Verify that the
panels are properly seated and that doors are closed.
4
8B
See
Table
22
CLM HARDWARE FAILURE
CLM failure.
4
8C 06
LOAD PO
RT DOOR OPEN
Load po
rt door unlocked but failed to open.
4
8E 02
SCSI UPGRADE TRANSFER FAILED
A data transfer error or a data storage error was received during the
rmware upgrade.
48E03
CABINET CONTROLLER UNABLE TO UPLOAD
Unable to upload rmware to the cabinet controller.
Retry the download.
Check cable connections.
Replace Smart M e dia and retry.
4
8E
04
ROBOTICS CONTROLLER UNABLE TO UPL OAD
Unable to upload rmware to the robotic controller. Verify that the
rmware image is correct and attempt to update again.
4
F2 00
I2C BUS COMMUNICATION FAILURE
Unable to communicate with the drive cluster.
Check I2C cable connection on the drive cluster.
Check that the cluster is powered on.
Check the LED status of the cluster controller.
HP StorageWorks
115