Maximizing Efficiency Through Data Replication Manager Data Movement Application Notes

Procedures and Examples
14 Application Notes - Maximizing Efficiency Through Data Replication Manager Data Movement
In the examples provided later for each topic, some displays show confirmation messages with the
event log symbol (%EVL) and an instance code. Information about instance codes and their meanings
can be found in the Compaq StorageWorks HSG80 Array Controller ACS Version 8.6 Troubleshooting
Reference Guide. The few instance codes that appear in the examples are described in Table 3.
Table 3: Instance Code Legend
Instance
Code Meaning
0E010064 A remote copy set has been created specified by the Remote Copy Set Name field.
The initiator unit of the remote copy set is specified by the initiator WWLID field.
0E020064 The remote copy set specified by the Remote Copy Set Name field has been deleted
by the operator.
0E030064 The logical unit specified by the target WWLID has transitioned from the normalizing
or copying state to the normal state.
0E050064 The logical unit specified by the target WWLID field has been added to the remote
copy set specified by the Remote Copy Set Name field. The new target member is
now in the normalizing state.
0E078A01 The logical unit specified by the target WWLID has been removed from the remote
copy set specified by the Remote Copy Set Name field. The target was removed by
the operator.
0E110064 The logical unit specified by the target WWLID field has transitioned from the merging
state to the normal state.
0E120064 The copy was terminated due to a write failure on the target unit. The write failure was
due to the links being down (target inaccessible). The copy will restart when at least
one link is restored. The initiator unit is specified by the Initiator WWLID field.
0E210064 The logical unit specified by the target WWLID field has transitioned from the normal
state to the write history logging state due to a remote connection event (the target
controllers are no longer accessible) or CLI SUSPEND command.
0E220064 The logical unit specified by the target WWLID field has transitioned from the logging
state to the merging state due to a remote connection event (the target controllers are
no longer accessible) or CLI RESUME command.