HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)
Configuring a Standard Data Replication Manager Solution
72 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Example:
a. Insert shortwave GBICs in ports 2 and 4 of both the top and bottom Fibre Channel
switches.
b. Connect a multimode, 50-micron fiber optic cable from port 1 of the top controller to
port 2 of the top Fibre Channel switch (as shown by callout 1 in Figure 17).
c. Connect a second multimode, 50-micron fiber optic cable from port 2 of the top
controller to port 4 of the top Fibre Channel switch (as shown by callout 2 in
Figure 17).
d. Connect a third multimode, 50-micron fiber optic cable from port 1 of the bottom
controller to port 2 of the bottom Fibre Channel switch (as shown by callout 3 in
Figure 17).
e. Connect a fourth multimode, 50-micron fiber optic cable from port 2 of the bottom
controller to port 4 of the bottom Fibre Channel switch (as shown by callout 4 in
Figure 17).
Figure 17 illustrates the cabling in the example. In this figure, the controllers are on the left
and the switches are on the right.
1
Cable from port 1 of the top controller to port 2 of the top Fibre Channel switch
2 Cable from port 2 of the top controller to port 4 of the top Fibre Channel switch
3 Cable from port 1 of the bottom controller to port 2 of the bottom Fibre Channel switch
4 Cable from port 2 of the bottom controller to port 4 of the bottom Fibre Channel switch
Figure 17: Cabling between the controllers and the Fibre Channel switches
CXO7086A
1
2
3
4