HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)
Zoning in the Storage Area Network
207Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Note: This configuration now becomes the effective (in use) configuration for both switches B
and Z.
11. To make this the active configuration after a restart or power-down, issue another
cfgSave command:
cfgSave
This ensures the effective configuration of the switches after a restart or power-down.
12. Verify that the Bottom_Fabric configuration is correct:
cfgShow
The system produces a display of the Bottom_Fabric configuration similar to the
following:
Defined configuration:
cfg: Bottom_Fabric
Blue Zone_Bottom; Brown Zone_Bottom; Green Zone_Bottom
Red Zone_Bottom; Yellow Zone_Bottom
zone: Blue Zone_Bottom
Host 2_Z; Controller Y1_bottom
zone: Brown Zone_Bottom
Host 4_Z; Controller Y1_bottom
zone: Green Zone_Bottom
Host 1_B; Controller A1_bottom
zone: Red Zone_Bottom
Controller A2_bottom; Controller Y2_bottom
zone: Yellow Zone_Bottom
Host 3_B; Controller A1_bottom
alias: Controller A1_bottom
0,4
alias: Controller A2_bottom
0,6
alias: Controller Y1_bottom
1,4
alias: Controller Y2_bottom
1,6
alias: Host 1_B
0,2
alias: Host 2_Z
1,2
alias: Host 3_B
0,8
alias: Host 4_Z
1,8