HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
145Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Documenting Your Configuration
IT Keep a copy of both configurations at both sites. Update your records whenever you modify
the configuration. Follow the steps outlined below in the sections titled “Terminal Emulator
Session” and “SHOW Commands” to obtain a status of the controllers, association sets,
remote copy sets, units, and connections. After you have obtained this information for the
initiator site, repeat the steps for the target site.
Terminal Emulator Session
IT
1. Connect a serial cable between a computer’s serial port and the HSG80 serial port. The
computer can be a desktop or laptop with at least one open serial port.
IT 2. Start a terminal emulator session and connect to the controller. The default connection
settings for the controllers are 9600 baud, 8 bits, no parity, 1 stop bit.
IT 3. From the Transfer menu, click Capture Text. In the c:\ field of the Capture Text dialog
box, type initiator.txt or target.txt.
IT 4. Click Start.
SHOW Commands
Note: SHOW commands are discussed in detail in Appendix A.
IT 1. To see the full information on this controller, issue the following CLI command:
SHOW THIS_CONTROLLER FULL
You should see a display similar to that in Example Display 52.
Example Display 52
Controller:
HSG80 ZG91412410 Software S050P-0, Hardware E05
NODE_ID = 5000-1FE1-0001-3AE0
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
Configured for MULTIBUS_FAILOVER with ZG91416136
In dual-redundant configuration
Device Port SCSI address 6
Time: NOT SET
Command Console LUN is lun 0 (NOIDENTIFIER)
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0001-3AE1
PORT_1_TOPOLOGY = FABRIC (fabric up)
Address = 220113
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0001-3AE2