HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
101Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
I 8. Verify that all controllers are on and functional by observing the CLI prompt on the
maintenance port of each controller.
Note: Unless otherwise specified, all operations may be conducted from the top controller
(controller A1).
I 9. Verify that the controllers are properly set up:
SHOW THIS_CONTROLLER
You should see a display similar to that in Example Display 24.
Example Display 24
Controller:
HSG80 ZG8nnnnnnn Software V87P, Hardware E03
NODE_ID = nnnn-nnnn-nnnn-nnnn
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-2
Not configured for dual-redundancy
Controller misconfigured -- other controller present
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is disabled
Host connection table is NOT locked
Smart error eject disabled
Host PORT_1:
Reported PORT_ID = nnnn-nnnn-nnnn-nnnn
PORT_1_TOPOLOGY = OFFLINE (offline)
Host PORT_2:
Reported PORT_ID = nnnn-nnnn-nnnn-nnnn
PORT_2_TOPOLOGY = OFFLINE (offline)
NOREMOTE_COPY
Cache:
512 megabyte write cache, version 0012
Cache is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
Mirrored Cache:
Not enabled
Battery:
FULLY CHARGED
Expires:
NOCACHE_UPS
Controller misconfigured. Type SHOW THIS_CONTROLLER