Data Replication Manager Windows-Based Server with Single Host Bus Adapter - Application Notes

Additional Considerations
Application Notes Data Replication Manager Windows-Based Server with Single Host Bus Adapter 15
Dual FC HBA Servers Running Microsoft Windows NT 4.0 / 2000
If a server with dual FC HBAs is connected to the SAN, zoning the FC fabric becomes mandatory, as
shown in Figure 10. There are a minimum of four zones that need to be created:
A zone containing port 1 of the top controllers in each HSG80 controller pair, as well as one FC
HBA from each dual FC HBA server. In the example, this is the "Red zone."
A zone containing port 1 of the bottom controllers in each HSG80 controller pair, as well as the
other FC HBA from each dual FC HBA server. In the example, this is the "Blue zone."
A zone containing host port 1 of both the top and bottom controller of each HSG80 controller pair,
as well as each single FC HBA server. In the example, this is the "Green zone."
A zone containing both host ports 1 and 2 of both the top and bottom controller of each HSG80
controller pair. In the example, this is the "Black zone." An optional SANworks Management
Appliance can be added to this zone.
Figure 10: Zoning with dual-FC HBA servers
Production Server
W2K or NT4
SAN Appliance
HBAHBA
HBAHBA
Production Server
W2K or NT4
HBAHBA
ISL
ISL
FC Switch
HSG80 controllers
Part of RED Zone
Part of BLUE Zone
Part of GREEN Zone
Part of BLACK Zone
Production Server
W2K or NT4
HBA
FC Switch
FC Switch
HSG80 controllers
FC Switch
Standby Server
W2K or NT4
HBAHBA
Standby Server
W2K or NT4
HBAHBA
Standby Server
W2K or NT4
HBA
CXO7871A