Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide

442 Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
You will see a display similar to the following:
Connection Unit
Name Operating system Controller Port Address Status Offset
HOSTA1 WINNT THIS 1 210013 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
HOSTA2 WINNT OTHER 1 200113 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
BUILDNGBA PPRC_TARGET THIS 2 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
BUILDNGBB PPRC_TARGET OTHER 2 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
BUILDNGBC PPRC_INITIATOR THIS 2 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
BUILDNGBD PPRC_INITIATOR OTHER 2 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
At the target site, the initiator host will appear as new connections, !NEWCONxx. These
should be renamed as described above.
Enable Access to the Hosts at the Initiator Site
1. The initiator units will need to have access to the hosts. Enable access with this
command:
SET UnitName ENABLE_ACCESS_PATH= InitiatorHostConnectionNamex,InitiatorHostConnectionNamey
Example: SET UnitName ENABLE_ACCESS_PATH=HostA1,HostA2
NOTE: Keep in mind that there should be two paths per host. You will need to repeat this
sequence for each host. Be sure to reboot the host after you have enabled hosts to access to
units.
2. Reboot the host.
3. Verify that Hszdisk has been installed. See Secure Path installation on page 42, Step 1.
4. Run Disk Administrator to create partitions, format, and assign drive letters on the
newly created storage. Once the storage has been configured with Disk Administrator,
you need to save this configuration to a floppy for use during a failover or failback
condition. To create a saved Windows NT configuration from the Disk Administrator,
perform the following steps:
a. Open Partition and select Configuration.