Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
4–40 Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
Figure 4–11. Data Replication Manager cabling at initiator and target sites
3. Verify that the connection between the host and the switch has been made by entering
this CLI command:
SHOW CONNECTIONS
NOTE: You can also verify that a connection has been made by looking for the illuminated green
LED that flashes on the switch ports.
You will see a display similar to the following:
Connection Unit
Name Operating system Controller Port Address Status Offset
!NEWCON00 WINNT THIS 1 210013 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
!NEWCON01 WINNT OTHER 1 200113 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
BUILDNGBA PPRC_TARGET THIS 2 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
BUILDNGBB PPRC_TARGET OTHER 2 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
BUILDNGBC PPRC_INITIATOR THIS 2 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
BUILDNGBD PPRC_INITIATOR OTHER 2 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
CXO7092A