Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
Configuring a Data Replication Manager Solution 4–37
5. To assign the log unit to the association set, use the following CLI command:
SET AssociationSetName LOG_UNIT = D10
Example: SET AS_D1 LOG_UNIT = D10
6. Check to see the switch status of the association set by issuing the following CLI
command:
SHOW AssociationSetName
Example: SHOW AS_D1
You will see a display similar to the following:
Name Association Uses Used by
-----------------------------------------------------------------------
AS_D1 association RC_D1
Switches:
NOFAIL_ALL
NOORDER_ALL
LOG_UNIT = D10 (No data logged)
Configure the Host
Install the Host Bus Adapters and Drivers
You should install two host bus adapters in each host system. If you are using Windows
NT, you will need to change the default Topology value from loop to switch. Follow the
procedures outlined. Refer to the KGPSA-BC PCI-to-Optical Fibre Channel Host Bus
Adapter User’s Guide for installation information.
1. To access REGEDT32, select START>>RUN, and type REGEDT32.
2. Find DriverSetting with the following sequence:
• HKEY_LOCAL_MACHINE
• SYSTEM
• CurrentControlSet
• Services
• Lp6nds35
• Parameters
• Device
• DriverParameters