Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
4–30 Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
Cabling the Initiator Site
Connect Fiber Optic Cables Between the Controllers and Switches
To better understand which ports you will be instructed to connect the cables to, Figure
4–7 shows the port locations on the switch.
Figure 4–7. Port Locations
1. Connect a multi-mode, 50-micron fiber optic cable from port 1 of the top controller to
port 2 of the top Fibre Channel switch.
2. Connect a second multi-mode, 50-micron fiber optic cable from port 2 of the top
controller to port 4 of the top Fibre Channel switch.
3. Connect a third multi-mode, 50-micron fiber optic cable from port 1 of the bottom
controller to port 2 of the bottom Fibre Channel switch.
4. Connect a fourth multi-mode, 50-micron fiber optic cable from port 2 of the bottom
controller to port 4 of the bottom Fibre Channel switch.
NOTE: You should see an illuminated green LED on the switch as soon as the cable is inserted
at both ends. This verifies that there is a good connection.
Figure 4–8 illustrates what your cabling should look like. The numbered callouts reflect
the steps that you just completed.
CXO7085A