Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide

426 Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
21. Verify that the CCL has been disabled by using the following CLI command:
SHOW THIS_CONTROLLER
The display will indicate that the CCL has been disabled:
Controller:
HSG80 ZG8nnnnnnn Software V85P, Hardware E03
NODE_ID = nnnn-nnnn-nnnn-nnnn
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-2
Configured for MULTIBUS_FAILOVER with ZG8nnnnnnn
In dual-redundant configuration
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is disabled
NOTE: For OpenVMS, use SCSI-3.
22. Verify that the settings you have established from controller A have been applied to
controller B by using the following CLI command:
SHOW OTHER_CONTROLLER
Proceed to step 24 if you are working in a Windows NT environment.
23. For OpenVMS, set the SCSI version, alloclass, and identifier with the following
commands:
SET THIS SCSI_VERSION = SCSI-3
SET ALLOCLASS = 1
SET THIS IDENTIFIER = 99
Setting this switch causes the host to load the SYS$GDRIVER, which provides the
GG devices. The value range is 1 - 99.
24. Check to see if mirrored write-back cache is enabled by using the following CLI
command:
SHOW THIS_CONTROLLER
You will see a display similar to the following:
Mirrored Cache:
Not enabled
.
.
.
If it is not enabled, issue the following CLI command:
SET THIS_CONTROLLER MIRRORED_CACHE
The controllers will restart after mirrored write-back cache has been set, and you will
see %LFL and %EVL displays.