Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
Configuring a Data Replication Manager Solution 4–25
The output will show that the controllers have been configured to support multiple
bus failover mode:
Controller:
HSG80 ZG8nnnnnnn Software V85P, Hardware E03
NODE_ID = nnnn-nnnn-nnnn-nnnn
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-2
Configured for MULTIBUS_FAILOVER with ZG8nnnnnnn
In dual-redundant configuration
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is disabled
NOTE: These settings will automatically be applied to controller B. Therefore, it is not necessary
to repeat these steps again on controller B.
17. Verify that the settings have been accepted on controller B by using the following CLI
command:
SHOW OTHER_CONTROLLER FULL
18. Change your controller prompts to help you easily identify which component you are
working on. Enter the following CLI commands:
SET THIS_CONTROLLER PROMPT=”InitiatorControllerNameTop> ”
SET OTHER_CONTROLLER PROMPT=”InitiatorControllerNameBottom> ”
Example: SET THIS_CONTROLLER PROMPT=”BuildngA> ”
Example: SET OTHER_CONTROLLER PROMPT=”BuildngB> ”
19. If you are working in an OpenVMS environment, proceed to step 23. If you are using
Windows NT, set the SCSI version to SCSI-2 and check to see if the Command
Console LUN (CCL) is disabled. Use the following CLI commands:
SET THIS SCSI_VERSION=SCSI-2
SHOW THIS_CONTROLLER
20. If the CCL is not disabled, issue the following CLI command:
SET THIS NOCOMMAND_CONSOLE_LUN