Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
4–24 Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
12. Once the worldwide name has been located, assign it to the controller using the
following CLI command:
SET THIS NODE_ID=node_ID checksum
The display should reflect the following:
Warning 4000: A restart of this controller is required before all the
parameters modified will take effect
%CER--HSG80> --09-FEB-1999 10:07:54-- Restart of this controller required
Restart of this controller required
13. Restart the controller using the following CLI command:
RESTART THIS_CONTROLLER
NOTE: Once you have restarted the controller, you will see a series of %LFL, %CER, and %EVL
prompts. These indicate a Last Failure Log, a CLI Event Report, and an Event Log, respectively.
For a complete explanation of the event reports, refer to the HSG80 Array Controller ACS Version
8.5 Maintenance and Service Guide.
14. Issue a SHOW THIS command to verify that the worldwide name has been set. You
should see a display similar to the following:
Controller:
HSG80 ZG8nnnnnnn Software V85P, Hardware E03
NODE_ID = nnnn-nnnn-nnnn-nnnn
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-2
Not configured for dual-redundancy
Controller misconfigured -- other controller present
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is disabled
.
.
.
15. Configure the controllers for multiple bus failover mode by issuing the following CLI
command:
SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER
This command automatically restarts the “other” controller.
You will see a %LFL and %EVL prompt. Refer to the HSG80 Array Controller
ACS Version 8.5 Maintenance and Service Guide for more details on these
reports.
16. To ensure that the settings from step 15 have been applied, enter:
SHOW THIS_CONTROLLER FULL