Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide

Configuring a Data Replication Manager Solution 419
4. Verify that the connection between the host and the switch has been made by entering
this CLI command:
SHOW CONNECTIONS
NOTE: You can also verify that a connection has been made by looking for the illuminated green
LED that flashes on the switch ports.
Figure 45. Cabling between the host and the switches
You will see a display similar to the following:
Connection Unit
Name Operating system Controller Port Address Status Offset
!NEWCON00 WINNT THIS 1 210013 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
!NEWCON01 WINNT OTHER 1 200013 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
CXO7088A
1
2