Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
4–18 Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
3. You can set the password and allow client access via the Secure Path Agent
Configuration.
NOTE: Compaq recommends that you set both the fully qualified and unqualified DNS names as
valid, authorized clients.
4. Reboot the host.
Install SWCC (optional)
Detailed information about SWCC can be found in the StorageWorks Command Console
Getting Started Guide.
Connect Fiber Optic Cables Between the Hosts and the Switches
Connecting the fiber optic cables involves two stages:
■ Cable Connection Procedure
■ Renaming the Host Connections
Both are described in the following sections.
Fiber Optic Cable Connection Procedure
1. Connect a multi-mode, 50-micron fiber optic cable from port 0 of the top switch to one
adapter on a host.
2. Connect the final multi-mode, 50-micron fiber optic cable from port 0 of the bottom
switch to the other adapter on the same host.
NOTE: You may choose any available port to connect your cables to, but you must maintain that
identical scheme at the initiator site. Therefore, if port 1 of controller B is connected to port 2 of
the bottom switch at the target site, then port 1 of controller B must be connected to port 2 of
the bottom switch at the initiator site.
3. If you have more than one host (up to four), connect one host bus adapter to one of the
remaining ports on the top switch. Connect the other host bus adapter to the same
numbered port on the bottom switch.
The host is now connected to the target site switches via the multi-mode, 50-micron fiber
optic cables. Your cabling should appear as it does in Figure 4–5.