Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide

410 Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
NOTE: These settings will be automatically applied to controller B. Therefore, it is not necessary
to repeat these steps again on controller B.
17. Verify that the settings have been accepted on controller B by using the following CLI
command:
SHOW OTHER_CONTROLLER FULL
18. Change your controller prompts to help you easily identify which controller you are
working on. Enter the following CLI commands:
SET THIS_CONTROLLER PROMPT=TargetControllerNameTop>
SET OTHER_CONTROLLER PROMPT=TargetControllerNameBottom>
Example: SET THIS_CONTROLLER PROMPT=BuildngBTop>
Example: SET OTHER_CONTROLLER PROMPT=BuildngBBottom>
19. If you are working in an OpenVMS environment, proceed to step 22. If you are using
Windows NT, disable the Command Console LUN (CCL) and set the SCSI version to
SCSI-2 by using the following CLI commands:
SET THIS NOCOMMAND_CONSOLE_LUN
SET THIS SCSI_VERSION = SCSI-2
20. Verify that the CCL has been disabled and that the SCSI version is set to SCSI-2 by
using the following CLI command:
SHOW THIS_CONTROLLER
The display will indicate that the CCL has been disabled:
Controller:
HSG80 ZG8nnnnnnn Software V85P, Hardware E03
NODE_ID = nnnn-nnnn-nnnn-nnnn
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-2
Configured for MULTIBUS_FAILOVER with ZG8nnnnnnn
In dual-redundant configuration
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is disabled
.
.
.
NOTE: For OpenVMS, use SCSI-3.
21. Verify that the settings you have established from controller A have been applied to
controller B by using the following CLI command:
SHOW OTHER_CONTROLLER
Proceed to step 23 if you are working in a Windows NT environment.