Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide

Configuring a Data Replication Manager Solution 49
NOTE: Once you have restarted the controller, you will see a series of %LFL, %CER, and %EVL
prompts. These indicate a Last Failure Log, a CLI Event Report, and an Event Log, respectively.
For a complete explanation of these event reports, refer to the HSG80 Array Controller ACS
Version 8.5 Maintenance and Service Guide.
14. Issue a SHOW THIS command to verify that the worldwide name has been set. You
should see a display similar to the following:
Controller:
HSG80 ZG8nnnnnnn Software V85P, Hardware E03
NODE_ID = yyyy-yyyy-yyyy-yyyy
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-2
Not configured for dual-redundancy
Controller misconfigured -- other controller present
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is disabled.
.
.
.
15. Configure for multiple bus failover mode by issuing the following CLI command:
SET MULTIBUS_FAILOVER COPY = THIS_CONTROLLER
This command automatically restarts the other controller.
You will see a %LFL and a %EVL prompt. Refer to the HSG80 Array Controller
ACS Version 8.5 Maintenance and Service Guide for more details on these
reports.
16. To ensure that the setting from step 15 has been applied, enter:
SHOW OTHER_CONTROLLER FULL
The resultant display will show that the controllers have been configured to support
multiple bus failover mode:
Controller:
HSG80 ZG8nnnnnnn Software V85P, Hardware E03
NODE_ID = nnnn-nnnn-nnnn-nnnn
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-2
Configured for MULTIBUS_FAILOVER with ZG8nnnnnnn
In dual-redundant configuration
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is disabled
.
.
.