Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
5–26 Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
3. To see information for all remote copy sets known to the controller pair, issue the
following CLI command:
SHOW REMOTE_COPY FULL
You should see a display similar to that in Example Display 3 for each remote copy set.
Example Display 3
Name Uses Used by
-----------------------------------------------------------------------
RC1 remote copy D1 AS1
Reported LUN ID: nnnnnnnnnnnnnnnnnnn
Switches:
OPERATION_MODE = SYNCHRONOUS
ERROR_MODE = NORMAL
FAILOVER_MODE = MANUAL
OUTSTANDING_IOS = 60
Initiator (LATHE\D1) state:
UNKNOWN - Request information from node LATHE
Target state:
ROUTER\D1 is NORMAL
4. To see information for all units configured to the controller, issue the following CLI
command:
SHOW UNITS FULL
You will see a display similar to that in Example Display 4 for each unit.