Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide

518 Compaq StorageWorks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide
To see information for all units configured to the controller, issue the
following CLI command:
SHOW UNITS FULL
You will see a display similar to the following for each unit:
D2 DISK10100 BuildingB\RC2
LUN ID: nnnnnnnnnnnnnnnnnnnnnn
NOIDENTIFIER
Switches:
RUN NOWRITE_PROTECT READ_CACHE
READAHEAD_CACHE WRITEBACK_CACHE
MAXIMUM_CACHED_TRANSFER_SIZE = 1
Access:
BuildngAA, BuildngAB, BuildngAC, BuildngAD, HostCon_1, HostCon_2
State:
ONLINE to this controller
Not reserved
PREFERRED_PATH = OTHER_CONTROLLER
Target NORMAL
Size: 17769177 blocks
Geometry (C/H/S): ( 5258 / 20 / 169 )
4. To see the connection name, operating system, controller, controller port, adapter ID
address, online or offline status, and unit offset, issue the following CLI command:
SHOW CONNECTIONS
You will see a display similar to the following for each connection:
Connection Unit
Name Operating system Controller Port Address Status
Offset !NEWCON28 WINNT THIS 1 634000 OL this 0
HOST_ID=1000-0000-C921-4B5B ADAPTER_ID=1000-0000-C921-4B5B
5. Save this file for future reference.