Diagnostics
97Edge Switch 2/24 Service Manual
12
Install an SFP optical transceiver in the port receptacle. Refer to “RRP: SFP
Optical Transceiver” on page 195.
■ This procedure is concurrent and can be performed while the switch is
powered on and operational.
■ Verify location of the failed port.
■ Perform an external loopback test for the port as part of FRU removal and
replacement. Refer to “Perform Loopback Tests” on page 160.
Exit MAP.
13
At the HAFM appliance, does a blinking red and yellow diamond (failed FRU
indicator) appear adjacent to a Fibre Channel port graphic at the Hardware View?
NO YES
↓ A port failure is indicated. Go to step 6.
14
Did a Fibre Channel port fail a loopback test?
NO YES
↓ Go to step 18.
15
Does a yellow triangle (attention indicator) appear adjacent to a port graphic at the
Hardware View?
YES NO
↓ Go to step 17.
Invalid Attachment Go to step 22.
Link Reset Go to step 33.
Not Installed Go to step 12.
Table 11: Port Operational States and Actions (EWS) (Continued)
Operational State Action