FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Diagnostics
94 Edge Switch 2/24 Service Manual
4
Is fault isolation being performed at the switch?
YES NO
↓ Fault isolation is being performed at the EWS interface or HAFM
appliance. Go to step 7.
5
Each port has an amber LED and a blue (2 Gb/s operation) or green (1 Gb/s
operation) LED adjacent to the port. The amber LED illuminates and the blue or
green LED extinguishes if the port fails.
Is an amber port LED illuminated but not blinking (beaconing)?
YES NO
↓ The switch appears operational, however a link incident or other
problem may have occurred. Perform fault isolation at the HAFM
appliance. Go to step 13.
Table 10: MAP 600 Event Codes
Event
Code
Explanation Action
080 Unauthorized worldwide name. Go to step 21.
081 Invalid attachment. Go to step 22.
506 Fibre Channel port failure. Go to step 6.
507 Loopback diagnostics port failure. Go to step 18.
512 SFP optical transceiver nonfatal error. Go to step 6.
514 SFP optical transceiver failure. Go to step 6.
581 Implicit incident. Go to step 34.
582 Bit error threshold exceeded. Go to step 34.
583 Loss of signal or loss of synchronization. Go to step 34.
584 Not operational primitive sequence received. Go to step 34.
585 Primitive sequence timeout. Go to step 34.
586 Invalid primitive sequence received for current link
state.
Go to step 34.