FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Diagnostics
91Edge Switch 2/24 Service Manual
11
Is fault isolation being performed at the EWS interface?
YES NO
Fault isolation is being performed at the HAFM appliance. Go to
step 16.
12
Does the EWS interface appear operational?
NO YES
Go to step 14.
13
A Page cannot be found, Unable to locate the server,
HTTP 404 - file not found, or other similar message appears. The
message indicates the PC cannot communicate with the switch because:
The switch-to-PC Internet link could not be established.
AC power distribution in the switch failed, or AC power was disconnected.
The switch CTP card failed.
The EWS interface is not operational and fault isolation must be performed at the
switch or HAFM appliance. Go to step 1. If this is the second time at this step,
contact the next level of support. Exit MAP.
14
Inspect fan module operational states at the EWS interface.
1. At the View panel, click the FRU Properties tab. The View panel (FRU
Properties tab) displays.
2. Inspect the Status fields for both power supplies.
Does the Status field display a Failed message for either fan module?
NO YES
A fan module failure is indicated. Go to step 6.
15
Inspect switch CTP operational states at the EWS interface. Inspect the Status
fields for the switch CTP.