Diagnostics
83Edge Switch 2/24 Service Manual
Note: The following steps describe inspecting the IP address using
HyperTerminal
serial communication software.
5. At the Windows Workstation menu, click Programs > Accessories >
Communications > HyperTerminal. The Connection Description dialog
box displays
6. Type Edge Switch 2/24 in the Name field and click OK. The Connect To
dialog box displays.
7. Ensure the Connect using field displays COM1 or COM2 (depending on the
serial communication port connection to the switch), and click OK. The
COMn dialog box displays, where n is 1 or 2.
8. Configure the Port Settings parameters as follows:
Bits per second115200.
Data bits8.
ParityNone.
Stop bits1.
Flow controlHardware or None.
When the parameters are set, click OK. The Edge Switch 2/24 -
HyperTerminal dialog box displays.
9. At the > prompt, type the user-level password (default is password) and
press Enter. The password is case sensitive. The Edge Switch 2/24 -
HyperTerminal dialog box displays with a C> prompt at the bottom of the
window.
10. At the C> prompt, type ipconfig and press Enter. The Edge Switch 2/24 -
HyperTerminal dialog box displays with configuration information listed,
including the IP address.
11. Record the switch IP address.
12. Click Exit from the File pull-down menu to close the HyperTerminal
application. A HyperTerminal dialog box displays.
13. Click Yes. A second HyperTerminal dialog box displays.
14. Click No to exit and close the HyperTerminal application.
15. Power off the maintenance terminal.