FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Diagnostics
74 Edge Switch 2/24 Service Manual
3
A Page cannot be found, Unable to locate the server,
HTTP 404 - file not found, or other similar message appears. The
message indicates the PC cannot communicate with the switch because:
The switch-to-PC Internet (Ethernet) link could not be established.
AC power distribution in the switch failed, or AC power was disconnected.
The switch CTP card failed.
Continue to the next step.
4
Ensure the switch is connected to facility AC power. Inspect the switch for
indications of being powered on, such as:
At the front bezel, an illuminated PWR LED (green) or ERR LED (amber).
Illuminated LEDs adjacent to Fibre Channel ports.
Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES NO
A power distribution problem is indicated. Go to “MAP 0100: Power
Distribution Analysis” on page 54. Exit MAP.
5
At the front of the switch, inspect the amber ERR LED.
Is the LED illuminated?
NO YES
A FRU failure or link incident is indicated. Go to “MAP 0000: Start
MAP” on page 32. Exit MAP.
6
Either a switch-to-PC Internet link problem (Internet too busy or IP address typed
incorrectly) or a switch Ethernet port failure is indicated.
1. Wait approximately five minutes, then attempt to login to the switch again.