FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Diagnostics
62 Edge Switch 2/24 Service Manual
4
POST/IPL diagnostics detected a FRU failure as indicated by event code 400 with
supplementary event data.
1. At the EWS Event Log or the Edge Switch Event Log, examine the first two
bytes (0 and 1) of event data associated with event code 400.
2. Byte 0 is a FRU code that indicates the failed component. Byte 1 is the slot
number of the failed FRU (00 for a nonredundant FRU, and 00 or 01 for
redundant FRUs).
Table 7 lists byte 0 FRU codes and associated steps that describe fault isolation
procedures.
5
The CTP card failed POSTs (as indicated by FRU code 02). Replace the switch.
Exit MAP.
6
A fan module failed POSTs (as indicated by FRU code 05) and the power supply
containing the fan must be removed and replaced. Refer to “RRP: Redundant
Power Supply” on page 198.
■ This procedure is concurrent and can be performed while switch power is on.
Table 6: MAP 200 Event Codes
Event
Code
Explanation Action
400 Power-up diagnostic
failure.
Go to step 4.
411 Firmware fault. Go to step 8.
Table 7: MAP 200 Byte 0 FRU Codes
Byte 0 Failed FRU Action
02 CTP card. Go to step 5.
05 Fan module. Go to step 6.
06 Power supply. Go to step 7.