FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Diagnostics
61Edge Switch 2/24 Service Manual
MAP 0200: POST Failure Analysis
When the switch is powered on, it performs a series of power-on self-tests
(POSTs). When POSTs complete, the switch performs an initial program load
(IPL) that loads firmware and brings the unit online. This MAP describes fault
isolation for problems that may occur during the POST/IPL process.
If an error occurs, the POST/IPL process continues in an attempt to initialize the
switch and bring it online. An event code 400 displays when the switch completes
the POST/IPL process.
1
Ensure the switch is connected to facility AC power. Inspect the switch for
indications of being powered on, such as:
■ At the front bezel, an illuminated PWR LED (green) or ERR LED (amber).
■ Illuminated LEDs adjacent to Fibre Channel ports.
■ Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES NO
↓ An AC power distribution problem is indicated, and analysis for the
failure is not described in this MAP. Go to “MAP 0100: Power
Distribution Analysis” on page 54. Exit MAP.
2
Was an event code 400 or 411 observed at the EWS Event Log or at the Edge
Switch Event Log (HAFM appliance)?
YES NO
↓ Analysis for the failure is not described in this MAP. Go to “MAP
0000: Start MAP” on page 32. Exit MAP.
3
Table 6 lists event codes, brief explanations of the codes, and the associated steps
that describe fault isolation procedures.