Diagnostics
59Edge Switch 2/24 Service Manual
21
Ensure the switch reporting the problem is connected to facility AC power. Inspect
the switch for indications of being powered on, such as:
■ At the front bezel, an illuminated PWR LED (green) or ERR LED (amber).
■ Illuminated LEDs adjacent to Fibre Channel ports.
■ Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES NO
↓ Go to step 13.
Analysis for an Ethernet link or a CTP failure is not described in this MAP. Go to
“MAP 0000: Start MAP” on page 32. If this is the second time at this step, contact
the next level of support. Exit MAP.
22
Inspect power supply operational states at the EWS interface.
1. At the View panel, click the FRU Properties tab. The View panel (FRU
Properties tab) displays.
2. Inspect the Status fields for both power supplies.
Does the Status field display a Failed message for either power supply?
NO YES
↓ A redundant power supply failed. Go to step 8.
The switch appears operational. Exit MAP.
23
At the HAFM appliance Hardware View, does a yellow triangle appear at the
alert panel and a blinking red and yellow diamond (failed FRU indicator) appear
to overlay a power supply graphic?
NO YES
↓ A redundant power supply failed. Go to step 8.