FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Diagnostics
55Edge Switch 2/24 Service Manual
2. At the HAFM appliance Hardware View, observe the graphic representing
the power supply and ensure a failure symbol (blinking red and yellow
diamond) does not appear.
Is a failure indicated?
YES NO
The switch appears operational. Exit MAP.
8
Visual inspection or an event code 200 or 201 indicates one or both power
supplies must be removed and replaced. Refer to “RRP: Redundant Power
Supply” on page 198.
This procedure is concurrent and can be performed while switch power is on.
Perform the data collection procedure as part of FRU removal and
replacement.
If multiple power supply failures occurred, connect the switch to facility AC
power after both power supplies are replaced.
Caution: Do not remove a power supply unless a replacement FRU is
immediately available. To avoid product overheating, a removed power supply
must be replaced within five minutes.
Did power supply replacement solve the problem?
NO YES
The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
9
Is fault isolation being performed at the switch?
YES NO
Fault isolation is being performed at the EWS interface or HAFM
appliance. Go to step 18.