FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Diagnostics
55Edge Switch 2/24 Service Manual
2. At the HAFM appliance Hardware View, observe the graphic representing
the power supply and ensure a failure symbol (blinking red and yellow
diamond) does not appear.
Is a failure indicated?
YES NO
↓ The switch appears operational. Exit MAP.
8
Visual inspection or an event code 200 or 201 indicates one or both power
supplies must be removed and replaced. Refer to “RRP: Redundant Power
Supply” on page 198.
■ This procedure is concurrent and can be performed while switch power is on.
■ Perform the data collection procedure as part of FRU removal and
replacement.
■ If multiple power supply failures occurred, connect the switch to facility AC
power after both power supplies are replaced.
Caution: Do not remove a power supply unless a replacement FRU is
immediately available. To avoid product overheating, a removed power supply
must be replaced within five minutes.
Did power supply replacement solve the problem?
NO YES
↓ The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
9
Is fault isolation being performed at the switch?
YES NO
↓ Fault isolation is being performed at the EWS interface or HAFM
appliance. Go to step 18.