FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Diagnostics
53Edge Switch 2/24 Service Manual
MAP 0100: Power Distribution Analysis
This MAP describes fault isolation for the switch power distribution system,
including defective AC power cords or redundant power supplies.
1
Was an event code 200 or 201, 202, 208 observed at the EWS Event Log or at the
Edge Switch Event Log (HAFM appliance)?
YES NO
↓ Go to step 9.
2
Table 5 lists event codes, brief explanations of the codes, and the associated steps
that describe fault isolation procedures.
3
Have the customer inspect and verify that facility power is within specifications.
These specifications are:
■ One single-phase connection for each power supply.
■ Input power between 100 and 240 VAC, and at least 5 amps.
■ Input frequency between 47 and 63 Hz.
Is facility power within specifications?
YES NO
↓ Ask the customer to correct the facility power problem. When facility
power is corrected, continue to the next step.
Table 5: MAP 100 Event Codes
Event
Code
Explanation Action
200 Power supply AC voltage failure. Go to step 3.
201 Power supply DC voltage failure. Go to step 8.
202 Power supply thermal failure. Go to step 8.
208 Power supply false shutdown. Go to step 3.